Old 08-30-2014, 04:37 PM #61
98OzarksRunner's Avatar
98OzarksRunner 98OzarksRunner is offline
Senior Member
 
Join Date: Oct 2010
Location: Ozark, MO
Posts: 1,068
98OzarksRunner is on a distinguished road
98OzarksRunner 98OzarksRunner is offline
Senior Member
98OzarksRunner's Avatar
 
Join Date: Oct 2010
Location: Ozark, MO
Posts: 1,068
98OzarksRunner is on a distinguished road
I realize this is an old thread (but still alive) and I appreciate the information, and plan to run some of this wiring. However, there is a problem, and a SERIOUS SAFETY ISSUE with this upgrade, specifically wire #8. The factory fuse link and 120 amp fuse are designed to protect the alternator, and the fuse link the rest of the vehicle wiring and components. By adding a second circuit with another 120 amp fuse, you are providing a 240 amp circuit when the engineers design it for 120 amp as a safety feature.

For example, if the fuse link blew (to protect the wiring and components in the vehicle), there would still be the second 120 amp path back through the fuse box via the alternator wire (#3 in your diagram). In reality, the fuse link would probably not blow at all until the total load reached 240 amps, when both fuses blow together (and maybe the fuse link). To make it simpler to understand, if the load reached 120 amps (the point the fuse should blow, by design) with this scenario, each circuit path would only have 60 amps flowing (since the current would be flowing equally in both paths), so neither fuse would blow (and your 4Runner might burn to the ground). In order to blow either 120 amp fuse, the load would have to reach 240 amps.

If you are going to use wire #8, you should pull off the fuse link (wire #1) and jumper the 120 amp alt fuse in the fuse box (or leave it be - a 120 amp fuse is essentially a jumper as far as the 30 amp fuse before it is concerned). That way the current from the battery will have 1 path, with a 120 amp fuse, to feed the fuse box and vehicle circuitry. The other option is to put a 60 amp fuse in each path (replace the 120 amp alternator fuse with a 60 amp, and use a 60 amp fuse on wire #8), for a total fuse capability if 120 amps.

I accidentally reversed the jumper cables while jump starting my wife's car recently and it blew the 120 amp alternator fuse, and 7 or 8 smaller ones. The 120 amp alternator fuse saved the alternator, ECM, and who knows what else. If it hadn't blow, I'd have been replacing lots of components and wiring harnesses (and maybe a car!) instead of 8 or 9 fuses.

Also, in your diagram, wire #8 connects to the 'B' terminal on the alternator, and the wire labeled as #3 is also the wire running from the 120 amp fuse to terminal 'B' on the alternator.
__________________
2002 T4R Limited, 191K miles - OME 883 front - LC 7 wrap/2nd gen sway bar links rear - Detroit Truetrac Diff - Cooper A/T3s - Warn M8000 - ARB Bumper - homemade (er, 'custom') rear bumper w/tire & can carrier - BajaRack - Diff Breather Mod - Hayden trans cooler - Yaesu 2M, Cobra CB - Fridge, off-road trailer with Tepui RTT (real expo poser)
In Africa they say: "Buy a Land Rover and it will take you anywhere. Buy a Toyota and it will take you there ... and bring you back home." jannikt on wranglerforum.com - I'm guessing he didn't make many friends there with that line.

Last edited by 98OzarksRunner; 08-30-2014 at 08:10 PM.
98OzarksRunner is offline   Reply With QuoteReply With Quote
Old 08-30-2014, 05:53 PM #62
BrianSD_42's Avatar
BrianSD_42 BrianSD_42 is offline
Elite Member
 
Join Date: Jan 2011
Location: San Diego
Age: 41
Posts: 11,437
Real Name: Instagram: briansd_97r
BrianSD_42 is just really nice BrianSD_42 is just really nice BrianSD_42 is just really nice BrianSD_42 is just really nice BrianSD_42 is just really nice
BrianSD_42 BrianSD_42 is offline
Elite Member
BrianSD_42's Avatar
 
Join Date: Jan 2011
Location: San Diego
Age: 41
Posts: 11,437
Real Name: Instagram: briansd_97r
BrianSD_42 is just really nice BrianSD_42 is just really nice BrianSD_42 is just really nice BrianSD_42 is just really nice BrianSD_42 is just really nice
So what you are saying is that looking at the diagram, the components to the right of the alternator are now exposed to a 240A short whereas before they were only exposed to 120A .... ?

Because the components to the left should be fine. Each path will blow if 120A is exceeded, same as factory.
Attached Images
Performing the "Big 3" Wiring Ugrade on a 3rd Gen T4R - A How To-tem999-jpg 
__________________
Those he commands move only in command, Nothing in love. Now does he feel his title, Hang loose about him, like a giant’s robe, Upon a dwarfish treasonous thief.

Last edited by BrianSD_42; 08-30-2014 at 05:57 PM.
BrianSD_42 is offline   Reply With QuoteReply With Quote
Old 08-30-2014, 05:56 PM #63
98OzarksRunner's Avatar
98OzarksRunner 98OzarksRunner is offline
Senior Member
 
Join Date: Oct 2010
Location: Ozark, MO
Posts: 1,068
98OzarksRunner is on a distinguished road
98OzarksRunner 98OzarksRunner is offline
Senior Member
98OzarksRunner's Avatar
 
Join Date: Oct 2010
Location: Ozark, MO
Posts: 1,068
98OzarksRunner is on a distinguished road
Quote:
Originally Posted by BrianSD_42 View Post
So what you are saying is that looking at the diagram, the components to the right of the alternator are now exposed to a 240A short whereas before they were only exposed to 120A .... ?

Because the components to the left should be fine. Each path will blow if 120A is exceeded, same as factory.
No. Two circuits (with the same resistance) in parallel, which is what this is, divide the total current flow equally between them. Since each path will flow equally, it will take 240 amps of current to blow EITHER of the fuses, which is twice the factory rating. As I said, if the total flow is 120 amps (which is where the factory fuse should blow) each fuse will only have 60 amps flowing through it (half the total current flow), so neither fuse will blow.

The safe way to do this is to remove (or disconnect) the wire from the fuse box to the alternator (wire #3 in the diagram) so there is only one fused path between the battery and the alternator (leave the fused link connected to the battery).
__________________
2002 T4R Limited, 191K miles - OME 883 front - LC 7 wrap/2nd gen sway bar links rear - Detroit Truetrac Diff - Cooper A/T3s - Warn M8000 - ARB Bumper - homemade (er, 'custom') rear bumper w/tire & can carrier - BajaRack - Diff Breather Mod - Hayden trans cooler - Yaesu 2M, Cobra CB - Fridge, off-road trailer with Tepui RTT (real expo poser)
In Africa they say: "Buy a Land Rover and it will take you anywhere. Buy a Toyota and it will take you there ... and bring you back home." jannikt on wranglerforum.com - I'm guessing he didn't make many friends there with that line.

Last edited by 98OzarksRunner; 09-23-2014 at 09:32 AM.
98OzarksRunner is offline   Reply With QuoteReply With Quote
Old 09-23-2014, 11:00 AM #64
IBallEngineer's Avatar
IBallEngineer IBallEngineer is offline
Senior Member
 
Join Date: Dec 2013
Location: Covina, CA
Posts: 2,301
IBallEngineer will become famous soon enough IBallEngineer will become famous soon enough
IBallEngineer IBallEngineer is offline
Senior Member
IBallEngineer's Avatar
 
Join Date: Dec 2013
Location: Covina, CA
Posts: 2,301
IBallEngineer will become famous soon enough IBallEngineer will become famous soon enough
Quote:
Originally Posted by 98OzarksRunner View Post
No. Two circuits (with the same resistance) in parallel, which is what this is, divide the total current flow equally between them. Since each path will flow equally, it will take 240 amps of current to blow EITHER of the fuses, which is twice the factory rating. As I said, if the total flow is 120 amps (which is where the factory fuse should blow) each fuse will only have 60 amps flowing through it (half the total current flow), so neither fuse will blow.

The safe way to do this is to remove (or disconnect) the wire from the fuse box to the alternator (wire #3 in the diagram) so there is only one fused path between the battery and the alternator (leave the fused link connected to the battery).
Let me start by saying I think the big 3 is big to do about almost nothing. I haven't done it to mine, nor do I intend to. 175K and no indication I will need it. Still I see the benefits IF, there is an alternator upgrade, or additional batteries, or you have not maintained the terminals/wires. So now to the problem.

Too many assumptions here. First the resistance in the two branches is NOT the same, that's the whole purpose of the upgrade. 2nd, if there would be a short to ground drawing big amperage, it would happen in an individual branch of the circuit. Since the current would take the path of least resistance, one branch fuse WOULD blow, most likely the added circuit breaker because that would be the path of least resistance. Of course you'd still have voltage, and therefore current flow because the 2nd branch would still be live. I haven't tested this, but I do think the 2nd fuse would then blow.

Now, if the alternator itself caused the short it would most likely draw all the battery could give, in which case 240A is nothing. Hell the starter could draw that much. Of course by design a short circuit anywhere in either branch would be just as catastrophic in terms of amperage draw.

And THAT is why this is really NOT a safety issue at all. Unless someone tells me that people doing the big 3 are burning their rigs to the ground.

That being said I agree with Ozark dude in that bypassing the original alternator circuit would be prudent. The redundancy is unnecessary anyway, and who wants to have to deal with a blown factory 120a fuse. Let the breaker do it's job and move on.

__________________
1989 FJ62 5.3 Chevy, FZJ80 Axles, 4.88's with ARB.
2000 2wd runner, 4 cylinders, yes it IS slow.
1999 4WD SR5 Desert Dune 3.4 351K and counting.
2000 4WD sport 3.4 Elocker <--My son's but I still end up paying.
2001 2WD SR5 3.4 <-- My daughter's...see preceding line.
IBallEngineer is offline   Reply With QuoteReply With Quote
Old 02-27-2015, 03:41 PM #65
T4Rfirefighter T4Rfirefighter is offline
Member
 
Join Date: Jun 2013
Location: Little Rock, AR
Posts: 165
T4Rfirefighter is on a distinguished road
T4Rfirefighter T4Rfirefighter is offline
Member
 
Join Date: Jun 2013
Location: Little Rock, AR
Posts: 165
T4Rfirefighter is on a distinguished road
I'm about to do my big 3 and need to know what size lugs to buy. Are most of the bolts 5/16", 3/8" or a mix? If they are a mix then I'll just drill the 5/16" lugs to make them fit.
__________________
2001 T4R SR5 - King 2.5" Coilovers, OME 890, 1" ToyTec BL, 285 Duratracs, CBI Hybrid, Warn M8000
T4Rfirefighter is offline   Reply With QuoteReply With Quote
Old 03-07-2015, 06:33 PM #66
T4Rfirefighter T4Rfirefighter is offline
Member
 
Join Date: Jun 2013
Location: Little Rock, AR
Posts: 165
T4Rfirefighter is on a distinguished road
T4Rfirefighter T4Rfirefighter is offline
Member
 
Join Date: Jun 2013
Location: Little Rock, AR
Posts: 165
T4Rfirefighter is on a distinguished road
Anybody know how to get access to the fusible link inside the fuse box? I'm trying to replace the stock wire with a larger/longer one and I can't figure out how to get to it.
__________________
2001 T4R SR5 - King 2.5" Coilovers, OME 890, 1" ToyTec BL, 285 Duratracs, CBI Hybrid, Warn M8000
T4Rfirefighter is offline   Reply With QuoteReply With Quote
Old 07-22-2015, 12:55 AM #67
gamefreakgc's Avatar
gamefreakgc gamefreakgc is offline
Elite Member
 
Join Date: Oct 2014
Location: Citrus Heights, California
Age: 36
Posts: 7,338
Real Name: Jerod
gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future
gamefreakgc gamefreakgc is offline
Elite Member
gamefreakgc's Avatar
 
Join Date: Oct 2014
Location: Citrus Heights, California
Age: 36
Posts: 7,338
Real Name: Jerod
gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future
Just did this one tonight. Should help out my idle and starts since my ground wire was a joke. Someone ripped it off and replaced it with some measly thin little wire. Now it's a beefy 4 gauge wire and sets the stage for the other lighting and audio projects to come and not have to worry about frying that tiny wire to oblivion.
__________________
'98 4Runner SR5 - 4x4 JDM 5VZ-FE Supercharged - 249K miles.
326WHP 347TQ

AEM F/IC 6, 11 PSI, 3" Intake and 3" Exhaust
Jerod's Supercharged T[u]RD Build
gamefreakgc is offline   Reply With QuoteReply With Quote
Old 07-22-2015, 01:48 PM #68
gamefreakgc's Avatar
gamefreakgc gamefreakgc is offline
Elite Member
 
Join Date: Oct 2014
Location: Citrus Heights, California
Age: 36
Posts: 7,338
Real Name: Jerod
gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future
gamefreakgc gamefreakgc is offline
Elite Member
gamefreakgc's Avatar
 
Join Date: Oct 2014
Location: Citrus Heights, California
Age: 36
Posts: 7,338
Real Name: Jerod
gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future gamefreakgc has a brilliant future
Wanted to share an update.

Driving the truck to work this morning and it idles MUCH better now. I think that's the gains to be had here, at idle it is smoother and has higher voltage. My wiring was damaged so I knew there was issues (had a few mechanics tell me the same thing) and when starting in extreme hot/cold conditions it was having trouble. Now runs like a top and it idle very smooth and about 200 RPM lower when cold and about ~50 RPM when hot. Very happy with how it turned out.

Other than my positive post being rusted together and my new terminal post being too big, this wasn't too bad. If if weren't for those hiccups I could have had it done in 2 hours or less.
__________________
'98 4Runner SR5 - 4x4 JDM 5VZ-FE Supercharged - 249K miles.
326WHP 347TQ

AEM F/IC 6, 11 PSI, 3" Intake and 3" Exhaust
Jerod's Supercharged T[u]RD Build
gamefreakgc is offline   Reply With QuoteReply With Quote
Old 12-20-2015, 02:57 PM #69
Bstrom's Avatar
Bstrom Bstrom is offline
Member
 
Join Date: Oct 2015
Location: Knoxville, TN
Posts: 266
Bstrom is on a distinguished road
Bstrom Bstrom is offline
Member
Bstrom's Avatar
 
Join Date: Oct 2015
Location: Knoxville, TN
Posts: 266
Bstrom is on a distinguished road
Quote:
Originally Posted by busmup808 View Post
Here are the battery posts that I bought from Napa they are military grade. Negative post us on the battery and the positive is not yet, due to me not finishing the POSITIVE wires upgrade with 120amp.
NOTE: Stud for wires are facing sideways, compared to facing upwards.
]
Just got these off eBay for $12 shipped and wanted to show them to the members looking for multiple post connection points.

Will be ordering ready made 4AWG cables after I take some dimensions. Great thread...
Attached Images
Performing the &quot;Big 3&quot; Wiring Ugrade on a 3rd Gen T4R - A How To-battery-posts-jpg 
__________________
Bstrom of Powell, TN
2003 Tundra | 1999 4Runner Limited 4WD | 2011 Mazda CX-7 Sport
Bstrom is offline   Reply With QuoteReply With Quote
Old 12-20-2015, 03:05 PM #70
jeremyc74 jeremyc74 is offline
Banned
 
Join Date: Nov 2014
Location: Palm Beach, FL
Posts: 1,388
jeremyc74 is on a distinguished road
jeremyc74 jeremyc74 is offline
Banned
 
Join Date: Nov 2014
Location: Palm Beach, FL
Posts: 1,388
jeremyc74 is on a distinguished road
I happened to be in West Marine (which is a boaters supply store) yesterday doing some Christmas shopping, and noticed they have a TON of large gauge wire and crimp connectors in there. You can buy the wire by the foot, and they had a crimping station set up where you could crimp the ends on right there in the store. That's a big deal, because a set of crimpers to do big cables like this the right way isn't cheap.

So, for anyone looking for parts to make this happen, check your local marine supplier. Most of the auto parts stores I've been in have a pretty limited selection of crimp connectors when you get up to these large sizes, and the don't sell the wire by the foot.
jeremyc74 is offline   Reply With QuoteReply With Quote
Old 12-20-2015, 04:17 PM #71
busmup808's Avatar
busmup808 busmup808 is offline
Senior Member
 
Join Date: Jan 2014
Location: From HI 2 WA
Posts: 1,684
busmup808 is a jewel in the rough busmup808 is a jewel in the rough busmup808 is a jewel in the rough busmup808 is a jewel in the rough
busmup808 busmup808 is offline
Senior Member
busmup808's Avatar
 
Join Date: Jan 2014
Location: From HI 2 WA
Posts: 1,684
busmup808 is a jewel in the rough busmup808 is a jewel in the rough busmup808 is a jewel in the rough busmup808 is a jewel in the rough
Quote:
Originally Posted by Bstrom View Post
Just got these off eBay for $12 shipped and wanted to show them to the members looking for multiple post connection points.

Will be ordering ready made 4AWG cables after I take some dimensions. Great thread...
These are nice. Are they military grade?
__________________
Busmup808 all day, all night!
busmup808 is offline   Reply With QuoteReply With Quote
Old 12-21-2015, 10:38 AM #72
Bstrom's Avatar
Bstrom Bstrom is offline
Member
 
Join Date: Oct 2015
Location: Knoxville, TN
Posts: 266
Bstrom is on a distinguished road
Bstrom Bstrom is offline
Member
Bstrom's Avatar
 
Join Date: Oct 2015
Location: Knoxville, TN
Posts: 266
Bstrom is on a distinguished road
Quote:
Originally Posted by busmup808 View Post
These are nice. Are they military grade?
I don't know what military grade actually means - care to offer a definition? They are eBay grade! You know what that means...

They are well made and plenty stout, and I hope the 'gauge' of steel used is equivalent to the electrical need. The nuts are Nylocks and the plastic pads are nice and heavy so I'm expecting them to be an improvement over other post designs.
__________________
Bstrom of Powell, TN
2003 Tundra | 1999 4Runner Limited 4WD | 2011 Mazda CX-7 Sport
Bstrom is offline   Reply With QuoteReply With Quote
Old 12-21-2015, 11:13 AM #73
infamousRNR's Avatar
infamousRNR infamousRNR is offline
Senior Member
 
Join Date: Dec 2013
Location: SF Bay Area California
Posts: 2,763
infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light
infamousRNR infamousRNR is offline
Senior Member
infamousRNR's Avatar
 
Join Date: Dec 2013
Location: SF Bay Area California
Posts: 2,763
infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light infamousRNR is a glorious beacon of light
Quote:
Originally Posted by Bstrom View Post
Just got these off eBay for $12 shipped and wanted to show them to the members looking for multiple post connection points.

Will be ordering ready made 4AWG cables after I take some dimensions. Great thread...



These are just what I've been looking for!!
What was your search term or the seller's ID??

Thanks!!!
__________________
1998 Desert Dune Toyota 4runner Limited 4x4 w/ factory e-locker
2000 BLACK Toyota 4runner Limited 4x4 w/ factory e-locker Build Thread
2002 Thundercloud Metalic Toyota 4runner Limited 4x4
Build Thread
infamousRNR is offline   Reply With QuoteReply With Quote
Old 12-21-2015, 12:31 PM #74
T4Rfirefighter T4Rfirefighter is offline
Member
 
Join Date: Jun 2013
Location: Little Rock, AR
Posts: 165
T4Rfirefighter is on a distinguished road
T4Rfirefighter T4Rfirefighter is offline
Member
 
Join Date: Jun 2013
Location: Little Rock, AR
Posts: 165
T4Rfirefighter is on a distinguished road
I am using car audio terminals from Toolmaker. 5 connections for each terminal.
__________________
2001 T4R SR5 - King 2.5" Coilovers, OME 890, 1" ToyTec BL, 285 Duratracs, CBI Hybrid, Warn M8000
T4Rfirefighter is offline   Reply With QuoteReply With Quote
Old 12-21-2015, 02:11 PM #75
busmup808's Avatar
busmup808 busmup808 is offline
Senior Member
 
Join Date: Jan 2014
Location: From HI 2 WA
Posts: 1,684
busmup808 is a jewel in the rough busmup808 is a jewel in the rough busmup808 is a jewel in the rough busmup808 is a jewel in the rough
busmup808 busmup808 is offline
Senior Member
busmup808's Avatar
 
Join Date: Jan 2014
Location: From HI 2 WA
Posts: 1,684
busmup808 is a jewel in the rough busmup808 is a jewel in the rough busmup808 is a jewel in the rough busmup808 is a jewel in the rough
Quote:
Originally Posted by T4Rfirefighter View Post
I am using car audio terminals from Toolmaker. 5 connections for each terminal.

Just goggled them and these are nice. Better than the other brands I was looking at. Thanks.
__________________
Busmup808 all day, all night!
busmup808 is offline   Reply With QuoteReply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is On

Forum Jump

Similar Threads
Thread Thread Starter Forum Replies Last Post
How "pre-wired" am I?? (E-Locker Wiring Help Needed) rickashay 3rd gen T4Rs 32 11-07-2016 06:57 PM
WTB: 4th Gen "4Runner," "Limited," and "Toyota" badges James_T Want to Buy/Trade 3 06-25-2011 11:42 AM
Zero point didnt work how to turn off "VSC TRAC" & "VSC OFF" & "ABS" lights sciff5 4th Gen T4Rs 6 09-27-2010 12:10 AM
"fog lights", front "grill?", and sport model questions mkingphoto 3rd gen T4Rs 2 03-31-2007 09:47 AM
problem solved. yipeeee. thanks to "live4swell" here & "jataga"from 4x4Wire. Michael Maintenance/Detailing 1 11-23-2004 01:29 PM

Powered by vBadvanced CMPS v3.2.2

All times are GMT -4. The time now is 05:17 AM.

Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Search Engine Optimisation provided by DragonByte SEO (Pro) - vBulletin Mods & Addons Copyright © 2024 DragonByte Technologies Ltd.
Feedback Buttons provided by Advanced Post Thanks / Like (Lite) - vBulletin Mods & Addons Copyright © 2024 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Lite) - vBulletin Mods & Addons Copyright © 2024 DragonByte Technologies Ltd.
***This site is an unofficial Toyota site, and is not officially endorsed, supported, authorized by or affiliated with Toyota. All company, product, or service names references in this web site are used for identification purposes only and may be trademarks of their respective owners. The Toyota name, marks, designs and logos, as well as Toyota model names, are registered trademarks of Toyota Motor Corporation***Ad Management plugin by RedTyger
 
Copyright © 2020